Self-cleaning filter is widely used equipment in water treatment industry. Its simple design and good performance enable sewage to achieve good filtering effect. The main components are: motor, electric control box, control pipeline, main pipe assembly, filter element assembly, 316L stainless steel brush, frame assembly, transmission shaft, inlet and outlet connecting flanges, etc. This kind of filter is a combination of technology and technology. With its advanced and reasonable structure, reliable performance, and easy operation, it is widely used in metallurgy, chemical industry, electric power, machinery, coal, paper pulping, and urban water supply. It can effectively remove mechanical impurities in industrial circulating water in the occasion of continuous water use in industries such as. Waste water, circulating water filtration, emulsion regeneration, pipeline filter waste oil filtration treatment, ironmaking, steelmaking, steel rolling, continuous casting water, blast furnace water, power system, etc. in the metallurgical industry.
Technical standards for the production of fully automatic self-cleaning filters:
1. In the production process, the hydraulic characteristics of the filter equipment are first confirmed by the measurement of pressure difference, flow rate, filter screen area and filter screen precision.
2. Flow measurement can confirm the output of the self-cleaning filter, and can also be used to confirm the fluid flow rate of backwashing, positive washing and various parts of the filter.
3. Temperature measurement Temperature measurement is for the filter to operate under the planned working conditions.
4. The confirmation of accuracy is based on the accuracy of the self-cleaning filter required by the customer to ensure that the accuracy value required by the customer is satisfied.
5. Chemical measurement Chemical measurement is mainly used to confirm the anti-corrosion performance of self-cleaning filter. The housing contains a selection of raw materials for cleaning components.
6. The quality of the water entering the self-cleaning filter meets the concentration scale value accepted by the self-cleaning filter to avoid frequent filter cleaning.
7. For the resistance loss test of the self-cleaning filter, the pressure measuring point is placed on the inlet and outlet pipes of the filter container.